Software/axiom: Difference between revisions

From National Optronics resources center
Jump to navigationJump to search
No edit summary
No edit summary
Line 27: Line 27:
=== New features ===
=== New features ===
=== Bugs fixed ===
=== Bugs fixed ===
* Passe size
* PT update time changed from 60 to 15
* New tangent algorithm
* New PID values
* Chuck protection reduce for lenses
* Calibration Wizard requires better precision on lens curve
* Internet server IP address updated.
* Bug#563: Sag gauge range
* Bug#615: Label "base curve" replaced by "sag value"
* Bug#009: Cutter algorithm position error for high curve
* Bug#262: We need to be able to cut wax
* Bug#271: When cutting flat curves (near plano) a lip can be present around the outer edge of the lens
* Bug#567: Laps with high cylinder are showing flat and with propellar marks
* Bug#582: The pin bevel applied is not flat and is inconsistent
* Bug#585: Surface finish on laps not comparable to 2G
* Bug#614: One lens job screen, base,cross and back curve are by default negative.
* Bug#287: Lap calibration use it own cycle speed
=== Download ===
=== Download ===
* Axiom USB software update [http://nationaloptronics.net/download/Axiom/software/AxiomUpdateUSB%201.04.08.exe (download)]
* Axiom USB software update [http://nationaloptronics.net/download/Axiom/software/AxiomUpdateUSB%201.04.08.exe (download)]
* Axiom finger print generator [http://nationaloptronics.net/download/Axiom/software/Axiom%20fingerprint%20V1.00.exe (download)]
* Axiom finger print generator [http://nationaloptronics.net/download/Axiom/software/Axiom%20fingerprint%20V1.00.exe (download)]

Revision as of 13:28, 9 May 2011

Version 1.04 RC

New features

  • Can backup DCS log on external thumb drive.
  • Can send DCS log over Internet.
  • If clear Job number machine than use internal tool and prism index.
  • Automatically save/restore config files using FingerPrint and DiskOnModule.
  • Check machine parameters and job data are valid before starting a cycle.
  • Multi-languages implemented.
  • Can use or ignore OMA block data.
  • Checks block data before starting a cycle.

Bugs fixed

  • Bug#438 After pulling up a new job the screen switch to the Lens screen.
  • Bug#186 Not a bug.
  • Bug#192 Need red message when an error occurs.
  • Bug#019 Can change serial port speed.
  • Bug#189 USB driver crash (not fixed: use new thumb drive)
  • Bug#438 Go to lens screen after downloading a job.
  • Bug#422 Use IFRNT if valid; if else use FRNT.
  • Bug#007 Use tool index and prism index to generate lens curve.

Download


Version 1.04.08 beta

New features

Bugs fixed

  • Passe size
  • PT update time changed from 60 to 15
  • New tangent algorithm
  • New PID values
  • Chuck protection reduce for lenses
  • Calibration Wizard requires better precision on lens curve
  • Internet server IP address updated.
  • Bug#563: Sag gauge range
  • Bug#615: Label "base curve" replaced by "sag value"
  • Bug#009: Cutter algorithm position error for high curve
  • Bug#262: We need to be able to cut wax
  • Bug#271: When cutting flat curves (near plano) a lip can be present around the outer edge of the lens
  • Bug#567: Laps with high cylinder are showing flat and with propellar marks
  • Bug#582: The pin bevel applied is not flat and is inconsistent
  • Bug#585: Surface finish on laps not comparable to 2G
  • Bug#614: One lens job screen, base,cross and back curve are by default negative.
  • Bug#287: Lap calibration use it own cycle speed

Download