6E: Difference between revisions

From National Optronics resources center
Jump to navigationJump to search
Line 22: Line 22:
* OMA LMATID 7 did not download correctly.
* OMA LMATID 7 did not download correctly.
;Download
;Download
* Software 2.17.02 & V3.11.03 [http://nationaloptronics.net/download/6E/software/6EUpdate.exe (download)]
* Software 2.17.02 & V3.11.03 [http://www.nationaloptronics.net/download/6E/software/6EUpdate.exe (download)]
* Help disk 2.01 [http://nationaloptronics.net/download/6E/software/6EHelp.exe (download)]
* Help disk 2.01 [http://www.nationaloptronics.net/download/6E/software/6EHelp.exe (download)]
 


=6EM Software=
=6EM Software=

Revision as of 14:36, 28 August 2015

Documentation

Manuals

English

Technical information

Probe Vertical Alignment Instructions (download)

Bevel Leadscrew Replacement Procedure (download)

6E Software

Version 2.17.02

New features
  • (none)
Bugs fixed
  • When a job is download as Hi-Idx with CPID of 1, the selected material is Hi-Idx.
  • Divots are occasionally cut into lens.
  • Edger sometimes freezes when probing small lenses.
  • OMA LMATID 7 did not download correctly.
Download

6EM Software

Version 1.06.01

New features
  • Add support for the shallow cutter.
  • Add new setup option to set a default finishing blade (one of 4 blades, or last blade).
Bugs fixed
  • (none)
Download


6ES Software

Version 1.13.01

New features
  • (none)
Bugs fixed
  • Pressing STOP during wet polishing would not abort the cycle.
  • During hub cleaning the mister solenoid would allow the maximum water flow.
Download